TORPEDO

Wet-type vaporizer ESA

Water bath, electrically heated, cabinet design · Ammonia (NH₃)

Design
Wet-type vaporizer, electrically heated (water bath)
Medium
Ammonia (NH₃)
Capacity
30–320 kg/h
Shape
cabinet, heat transfer medium: inhibited antifreeze/water mixture
Pressure rating
PN 25, test pressure 36 bar
Connections
to customer specification
Explosion protection
Zones 1 and 2; control cabinet outside the hazardous area
Codes and standards
PED 2014/68/EU, AD 2000-Merkblatt HP 801 No. 34

Send an enquiry Ammonia brochure

Wet-type vaporizer ESA in cabinet design with shut-off valves and drip tray

How it works

The ESA series is indirectly electrically heated and works with a liquid heat transfer medium based on a mixture of antifreeze, inhibitors and water. The vaporizer coil is immersed in the water bath (wet-type vaporizer).

The advantage is that heater ratings and heat transfer surfaces are easier to adapt, even for demanding tasks. The tube coil and heating system are separate and fully repairable. The control cabinet using thermostat and relay technology is easy to maintain and can be adapted to various requirements.

The ESA series is suitable for larger demand, for operating conditions outside saturation conditions, for installation in hazardous area Zones 1 and 2 and for increased requirements for control or evaluation of operating parameters. The control cabinet is installed outside the hazardous area.

Sizes

TypeCapacity NH₃
kg/h
Connected load
kW
W × H × L
mm
Empty weight approx.
kg
ESA 303019435 × 1280 × 730110
ESA 606037535 × 1295 × 845240
ESA 10010055535 × 1660 × 845310
ESA 13013073535 × 1660 × 845320
ESA 16016091535 × 1885 × 1195430
ESA 20020091535 × 1885 × 1195470
ESA 260260113.5535 × 2030 × 1195550
ESA 320320113.5535 × 2030 × 1195on request

Voltage 400 V. Values for the standard version; we adapt wet-type vaporizers to the order and the place of use. For very small quantities, the dry-type vaporizer ETA8TO is the more economical choice.

Same design for propane / LPG Wet-type vaporizer ES · 60–1,400 kg/h

To size your vaporizer, we need some details about gas, storage and operation: Planning notes for ammonia (NH₃) →

Planning a gas supply system?

We advise you on sizing, from the first question to the turnkey station.

We look forward to your enquiry:

info@torpedo-online.de

04106 / 62 77-0